LogoLogoMSF Science Portal
  • My saved items
logo

© Médecins Sans Frontières

MSF Science Portal
About MSF Science Portal
About MSF
Contact Us
Frequently Asked Questions (FAQs)
Privacy Policy
Terms of Use

v2.1.4829.produseast1

3 result(s)
Filter and sort
3 result(s)
Journal Article > ResearchFull Text

Demonstration of the diagnostic agreement of capillary and venous blood samples, using hepatitis-C virus SD Bioline © rapid test: A clinic-based study

J Clin Virol. 1 February 2019; Volume 111; 39-41.; DOI:10.1016/j.jcv.2018.12.008
Sun C, Iwamoto M, Calzia A, Sreng B, Yann S,  et al.
J Clin Virol. 1 February 2019; Volume 111; 39-41.; DOI:10.1016/j.jcv.2018.12.008
BACKGROUND
Simplifying hepatitis C virus (HCV) screening is a key step in achieving the elimination of HCV as a global public health threat by 2030.

OBJECTIVES
The objective of this study was to demonstrate the agreement of capillary blood and venipuncture specimens when using SD Bioline© HCV, a low-cost rapid diagnostic test (RDT), prequalified by WHO in 2016 on venous blood samples.

STUDY DESIGN
Recruitment was conducted prospectively among adult patients presenting for HCV testing at the Médecins Sans Frontières (MSF) clinic of Preah Kossamak Hospital (Phnom Penh, Cambodia) between October and November 2017. Capillary and venous blood samples were collected from consenting patients and tested with SD Bioline© HCV. Two independent, blinded readers, and in the case of disagreement, a third reader, interpreted the results of each blood sample. Concordance between results was compared using Cohen's Kappa interrater reliability statistic. Discrepant sample pairs were tested with an enzyme immunoassay, the reference standard, at the Institute Pasteur of Cambodia.

RESULTS
Among 421 pairs of samples collected, reader disagreement occurred for 0.7% (n = 3) of the participants. Sixty-four percent of capillary and venous blood sample pairs tested positive for HCV, with a Kappa statistic of 0.985 between the two methods. Three participants with discrepant sample pair results tested positive with EIA.

CONCLUSIONS
Capillary and venous blood samples were concordant when tested with HCV SD Bioline© in a clinical context. This simplified testing approach is essential to the scale-up of HCV screening and useful in resource-limited settings or among populations for whom venipuncture is problematic.
More
Journal Article > ResearchFull Text

Ebola Virus Disease: An Update On Current Prevention and Management Strategies

J Clin Virol. 11 November 2016; Volume 86; DOI:10.1016/j.jcv.2016.11.005
Trad MA, Naughton W, Yeung A, Mazlin L, O’sullivan M,  et al.
J Clin Virol. 11 November 2016; Volume 86; DOI:10.1016/j.jcv.2016.11.005
Ebola virus disease (EVD) is characterised by systemic viral replication, immuno-suppression, abnormal inflammatory responses, large volume fluid and electrolyte losses, and high mortality in under-resourced settings. There are various therapeutic strategies targeting EVD including vaccines utilizing different antigen delivery methods, antibody-based therapies and antiviral drugs. These therapies remain experimental, but received attention following their use particularly in cases treated outside West Africa during the 2014-15 outbreak, in which 20 (80%) out of 25 patients survived. Emerging data from current trials look promising and are undergoing further study, however optimised supportive care remains the key to reducing mortality from EVD.More
Journal Article > ResearchFull Text

Demonstration of the diagnostic agreement of capillary and venous blood T samples, using hepatitis-C virus SD Bioline rapid test: A clinic-based study

J Clin Virol. 1 September 2019; Volume 111; 39-41.; DOI:10.1016/j.jcv.2018.12.008
Sun C, Iwamoto M, Calzia A, Sreng B, Yann S,  et al.
J Clin Virol. 1 September 2019; Volume 111; 39-41.; DOI:10.1016/j.jcv.2018.12.008
BACKGROUND
Simplifying hepatitis C virus (HCV) screening is a key step in achieving the elimination of HCV as a global public health threat by 2030.

OBJECTIVES
The objective of this study was to demonstrate the agreement of capillary blood and venipuncture specimens when using SD Bioline© HCV, a low-cost rapid diagnostic test (RDT), prequalified by WHO in 2016 on venous blood samples.

STUDY DESIGN
Recruitment was conducted prospectively among adult patients presenting for HCV testing at the Médecins Sans Frontières (MSF) clinic of Preah Kossamak Hospital (Phnom Penh, Cambodia) between October and November 2017. Capillary and venous blood samples were collected from consenting patients and tested with SD Bioline© HCV. Two independent, blinded readers, and in the case of disagreement, a third reader, interpreted the results of each blood sample. Concordance between results was compared using Cohen's Kappa interrater reliability statistic. Discrepant sample pairs were tested with an enzyme immunoassay, the reference standard, at the Institute Pasteur of Cambodia.

RESULTS
Among 421 pairs of samples collected, reader disagreement occurred for 0.7% (n = 3) of the participants. Sixty-four percent of capillary and venous blood sample pairs tested positive for HCV, with a Kappa statistic of 0.985 between the two methods. Three participants with discrepant sample pair results tested positive with EIA.

CONCLUSIONS
Capillary and venous blood samples were concordant when tested with HCV SD Bioline© in a clinical context. This simplified testing approach is essential to the scale-up of HCV screening and useful in resource-limited settings or among populations for whom venipuncture is problematic.
More