Journal Article > ResearchFull Text
Trop Med Int Health. 2004 April 1; Volume 9 (Issue 4); DOI:10.1111/j.1365-3156.2004.01217.x
Checchi F, Piola P, Kosack CS, Ardizzoni E, Klarkowski DB, et al.
Trop Med Int Health. 2004 April 1; Volume 9 (Issue 4); DOI:10.1111/j.1365-3156.2004.01217.x
We report below an in vivo antimalarial efficacy study conducted in 2002 in Bundi Bugyo, a district of western Uganda housing a large displaced population. We tested sulfadoxine-pyrimethamine (SP), amodiaquine (AQ) and the combination chloroquine plus SP (CQ + SP). A total of 268 children with uncomplicated Plasmodium falciparum malaria were followed-up for 28 days according to WHO recommendations, with PCR genotyping to distinguish late recrudescences from re-infections. PCR-adjusted failure proportions at day 28 were 37.0% (34/92, 95% CI 27.1-47.7) in the SP group, 20.6% (14/68, 95% CI 11.7-32.1) in the AQ group and 22.8% (18/79, 95% CI 14.1-33.6) in the CQ + SP group. Early failures were particularly frequent in the SP group (15.2%). Clearance of gametocytes was slower in the SP and CQ + SP groups than in the AQ group. This study suggests that, in Bundi Bugyo, CQ + SP (Uganda's first-line regimen) will need to be replaced by a more efficacious regimen. Across Uganda, the deployment of SP containing combinations may not be a feasible long-term strategy. For Bundi Bugyo, we recommend a combination of artesunate and AQ. Our study also confirms previous findings that resistance is considerably underestimated by 14-day follow-ups. Antimalarial policy decisions should therefore be based on 28-day studies, with PCR adjustment to distinguish re-infections.
Journal Article > ResearchFull Text
PLOS One. 2009 February 6; Volume 4 (Issue 2); e4351.; DOI:10.1371/journal.pone.0004351
Klarkowski DB, Wazome JM, Lokuge K, Shanks L, Mills C, et al.
PLOS One. 2009 February 6; Volume 4 (Issue 2); e4351.; DOI:10.1371/journal.pone.0004351
BACKGROUND
Concerns about false-positive HIV results led to a review of testing procedures used in a Médecins Sans Frontières (MSF) HIV programme in Bukavu, eastern Democratic Republic of Congo. In addition to the WHO HIV rapid diagnostic test algorithm (RDT) (two positive RDTs alone for HIV diagnosis) used in voluntary counselling and testing (VCT) sites we evaluated in situ a practical field-based confirmation test against western blot WB. In addition, we aimed to determine the false-positive rate of the WHO two-test algorithm compared with our adapted protocol including confirmation testing, and whether weakly reactive compared with strongly reactive rapid test results were more likely to be false positives.
METHODOLOGY/PRINCIPAL FINDINGS
2864 clients presenting to MSF VCT centres in Bukavu during January to May 2006 were tested using Determine HIV-1/2 and UniGold HIV rapid tests in parallel by nurse counsellors. Plasma samples on 229 clients confirmed as double RDT positive by laboratory retesting were further tested using both WB and the Orgenics Immunocomb Combfirm HIV confirmation test (OIC-HIV). Of these, 24 samples were negative or indeterminate by WB representing a false-positive rate of the WHO two-test algorithm of 10.5% (95%CI 6.6-15.2). 17 of the 229 samples were weakly positive on rapid testing and all were negative or indeterminate by WB. The false-positive rate fell to 3.3% (95%CI 1.3-6.7) when only strong-positive rapid test results were considered. Agreement between OIC-HIV and WB was 99.1% (95%CI 96.9-99.9%) with no false OIC-HIV positives if stringent criteria for positive OIC-HIV diagnoses were used.
CONCLUSIONS
The WHO HIV two-test diagnostic algorithm produced an unacceptably high level of false-positive diagnoses in our setting, especially if results were weakly positive. The most probable causes of the false-positive results were serological cross-reactivity or non-specific immune reactivity. Our findings show that the OIC-HIV confirmation test is practical and effective in field contexts. We propose that all double-positive HIV RDT samples should undergo further testing to confirm HIV seropositivity until the accuracy of the RDT testing algorithm has been established at programme level.
Concerns about false-positive HIV results led to a review of testing procedures used in a Médecins Sans Frontières (MSF) HIV programme in Bukavu, eastern Democratic Republic of Congo. In addition to the WHO HIV rapid diagnostic test algorithm (RDT) (two positive RDTs alone for HIV diagnosis) used in voluntary counselling and testing (VCT) sites we evaluated in situ a practical field-based confirmation test against western blot WB. In addition, we aimed to determine the false-positive rate of the WHO two-test algorithm compared with our adapted protocol including confirmation testing, and whether weakly reactive compared with strongly reactive rapid test results were more likely to be false positives.
METHODOLOGY/PRINCIPAL FINDINGS
2864 clients presenting to MSF VCT centres in Bukavu during January to May 2006 were tested using Determine HIV-1/2 and UniGold HIV rapid tests in parallel by nurse counsellors. Plasma samples on 229 clients confirmed as double RDT positive by laboratory retesting were further tested using both WB and the Orgenics Immunocomb Combfirm HIV confirmation test (OIC-HIV). Of these, 24 samples were negative or indeterminate by WB representing a false-positive rate of the WHO two-test algorithm of 10.5% (95%CI 6.6-15.2). 17 of the 229 samples were weakly positive on rapid testing and all were negative or indeterminate by WB. The false-positive rate fell to 3.3% (95%CI 1.3-6.7) when only strong-positive rapid test results were considered. Agreement between OIC-HIV and WB was 99.1% (95%CI 96.9-99.9%) with no false OIC-HIV positives if stringent criteria for positive OIC-HIV diagnoses were used.
CONCLUSIONS
The WHO HIV two-test diagnostic algorithm produced an unacceptably high level of false-positive diagnoses in our setting, especially if results were weakly positive. The most probable causes of the false-positive results were serological cross-reactivity or non-specific immune reactivity. Our findings show that the OIC-HIV confirmation test is practical and effective in field contexts. We propose that all double-positive HIV RDT samples should undergo further testing to confirm HIV seropositivity until the accuracy of the RDT testing algorithm has been established at programme level.
Journal Article > ResearchFull Text
Virol J. 2015 May 14; Volume 12 (Issue 1); DOI:10.1186/s12985-015-0306-4
Shanks L, Siddiqui MR, Abebe A, Piriou E, Pearce N, et al.
Virol J. 2015 May 14; Volume 12 (Issue 1); DOI:10.1186/s12985-015-0306-4
Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results.